Operation procedure of spectral confocal sensor

  When using a spectral confocal sensor, a calibration procedure should be performed to ensure measurement accuracy. So, what are the operation steps of the spectral confocal sensor? Shenzhen Liyi Technology small edition for you to share:



Operation steps of spectral confocal sensor:


1, In order to ensure the accuracy of each measurement result, almost all measuring equipment or system work needs to be calibrated before use. Although the devices and systems measured in the factory are subject to a rigorous calibration process. In the use of environmental factors such as temperature, humidity, vibration and light changes, the measurement equipment and system may be disturbed, the measurement accuracy will be greatly affected. When using a spectral confocal measuring device or system, a calibration procedure should be performed in order to ensure measurement accuracy.

2, spectral confocal sensor guide equipment, wait 15 minutes after the machine reaches the state of thermal balance; Raising the probe without measuring the range of any debris to ensure that, to achieve better handling, it is recommended to use a fully covered sheet of paper and measuring head; The key is to squeeze the operating software interface of the dark signal processing device, or by pressing the physical button in the dark signal acquisition device panel, the light intensity measurement signal indicator flashes until the dark signal acquisition process is complete.

3. The three colors of the LED signal light on the panel are determined according to the comparison results, and the dark green signal level indicates the frequency measurement in the dark signal processing device to meet all the requirements; Dark orange indicates that the current signal level is too high, but still sufficient for high frequency measurement applications; The red dark current signal level is too high to be used to measure the dark signal being re-acquired.

4. The measuring head is connected to the control panel to pull the optical fiber plug, and the collection of dark signals, such as the LED indicator showing green, the problem derived from the measuring head part, the measuring head connection can exist optical interface dust pollution, gently wipe the optical interface cotton swab with alcohol. If the test does not work, the optical fiber may be damaged, it is recommended to replace the optical fiber.


The above is about the operation steps of the spectral confocal sensor to share this, want to know more about the spectral confocal displacement sensor friends can call the online customer service hotline of Lihe technology to understand.